-40%
250' Aluminum Quadruplex Cable URD 4-4-4-4 Tulsa 600 Volt Wire 250'
$ 140.44
- Description
- Size Guide
Description
Up for sale is brand new 250' of 4-4-4-4 Aluminum URD, code name Tulsa.Aluminum Jacketed Quadruplex Conductor Underground Cable
Aluminum Jacketed Quadruplex Conductor Underground Power Cable
600V XLPE Insulation & HDXLPE Jacket
Aluminum Jacketed Quadruplex Conductor Underground Power Cable Construction:
Complete Cable:
Three phase conductors and one neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
Twisted cables form a quadruplex assembly
Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
Conductors:
Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
Insulation & Jacket:
Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
The three phase conductors are black and the neutral conductor is black identified by three extruded yellow stripes.
Aluminum Jacketed Quadruplex Conductor Underground Power Cable Features and Benefits:
Insulation/Jacket system provide very high degree of protection against insulation damage from unclean backfill material and cuts and abrasions from installation
For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications
Aluminum Jacketed Quadruplex Conductor Underground Power Cable Applications:
Intended for use in underground systems operated at 600 volts or less.
Aluminum Jacketed Quadruplex Conductor Underground Power Cable Options:
Aluminum 1350-H16 conductor
Copper conductors
Other neutral identification methods
Sizes 250-500 kcmil available with UL-allowed thin wall (0.080") insulation
CDC Combined Duct & Cable
Reeless Package
PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
Type USE-2 per UL 44
Part #
Phase Conductor AWG
Phase Conductor Stranding
Phase Conductor Insul. Thick. Mils
Neutral AWG
Neutral Stranding
Neutral Insul. Thick. Mils
Cable OD Single Phase Mils
Cable OD Complete Cable Inches
Lbs./M'
TULSA
4
7
60
4
7
60
.35
.85″
249
WITTENBERG
2
7
60
2
7
60
.41
.99″
382
Miami
2
7
60
6
7
60
.41
.99″
333
DYKE
2
7
60
4
7
60
.41
.93″
334
Notre Dame
1/0
19
80
2
7
60
.53
1.28″
534
PURDUE
1/0
19
80
1/0
19
80
.53
1.28″
614
SYRACUSE
2/0
19
80
1
19
80
.57
1.31″
657
LAFAYETTE
2/0
19
80
2/0
19
80
.57
1.39″
744
DAVIDSON
3/0
19
80
3/0
19
80
.62
1.51″
903
SWARTHMORE
3/0
19
80
1/0
19
80
.62
1.51″
831
Doane
4/0
19
80
1/0
19
80
.68
1.64″
981
Wake Forest
4/0
19
80
2/0
19
80
.68
1.55″
974
Mc Pherson
4/0
19
80
2
7
60
.68
1.64″
924
EARLHAM
4/0
19
80
4/0
19
80
.68
1.64″
1104
RUST
250
37
95
3/0
19
80
.76
1.73″
1183
Palomar
250
37
95
250
37
95
.76
1.83″
1316
Niagara
350
37
95
350
37
95
.86
2.08″
1760
Slippery Rock
350
37
95
4/0
19
80
.86
2.08″
1544
Wofford
500
37
95
350
37
95
.99
2.39″
2251
Morehouse
500
37
95
300
37
95
.99
2.39″
2196
Marshall
500
37
95
500
37
95
.99
2.39″
2415
Westminster
750
61
110
350
37
95
1.20
2.89″
3102
Tabor
750
61
110
750
61
110
1.20
2.89″
3550
Windham
750
61
110
500
37
95
1.20
2.89″
3266
FREE SHIPPING!!
Please note that sales tax will be added to the following states: AZ, AR, CA, CO, CT, FL, GA, ME, MD, MN, NE, NV, NJ, NY, OH, PA, SD, TX